Key Specifications
NUMBER OF CHANNELS
4 to 100 (single unit)SAMPLING RATE
shortest scan interval: 1msMEMORY
500 MB/ 1.2 GB (internal), 32 GB (SD)TYPE OF MEASUREMENT
DC voltage, Standard signal,Thermocouple, RTD, Digital input,
DC current, resistance
Features
Profile function delivers real-time warnings of abnormalities
By creating a profile waveform from past recorded data and loading it into GX/GP, this waveform can be used as a threshold for process values. Profile waveforms are useful in applications where process values change over time. Also, you can see the deviation from the reference waveform on the screen.
Maximum number of channels: 20
Shortest recording interval: 500 ms
*/MC option required
An intuitive UI engineered for ease-of-use Efficiently search for key data
Seamless display of historical trends—flick or drag the trend display to scroll through the data, even during measurement.
Quickly find data using calendars and summary screens
From a calendar, jump to waveforms of a specific date. From the alarm summary, jump to the waveform active during the alarm.
Check waveforms of concern in detail
Display digital values at any location
Move the scale to display the value corresponding to that position as a numeric value. Instantly check maximum/minimum measured values.
Ascertain long-duration trends at a glance
All historical trends display
Long-duration trends can be fitted to a single screen for easy viewing.
Zoom in/out - time axis and engineering units
The time axis and engineering axis can expanded and compressed using a simple pinch together or apart function
Wide variety of input/output modules
Model | Name | Measurement/Application | Channels |
---|---|---|---|
GX90XA-10-U2 | Analog input module | DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (solid state relay scanner type) | 10 |
GX90XA-10-L1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Low withstand voltage solid state relay scanner type) | 10 | |
GX90XA-10-T1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (electromagnetic relay scanner type) | 10 | |
GX90XA-10-C1 | DC current (mA) (solid state relay scanner type) | 10 | |
GX90XA-10-V1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Solid state relay scanner type) | 10 | |
GX90XA-04-H0 | DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (individual A/D type) | 4 | |
GX90XA-06-R1 | 4-wire RTD, 4-wire resistance (solid state relay scanner type) | 6 | |
GX90YA | Analog output module | Current output | 4 |
GX90XD | Digital input module | Remote control input or operation recording | 16 |
GX90YD | Digital output module | Alarm output | 6 |
GX90WD | Digital input/output module | Remote control input or operation recording/alarm output | DI:8/DO:6 |
GX90XP | Pulse input module | Pulse signal data acquisition, integral count | 10 |
GX90UT | PID control module | PID control (2 loop) | AI:2/AO:2 DI:8/DO:8 |
Model
Model | Channels | Bandwidth | Sampling Rate | Number of modules | Memory | Measurement type | Power |
---|---|---|---|---|---|---|---|
GP10 | 4 to 100 (single unit) | N/A | min. 1 ms (Scan interval) | 3 (each modules contain 4 to 10 channels) |
500 MB/ 1.2 GB (internal), 32 GB (SD) | DC voltage, Standard signal, Thermocouple, RTD, Digital input, DC current`, resistance | 100 to 240 VAC 12 VDC |
GP20 | 4 to 100 (single unit) | N/A | min. 1 ms (Scan interval) | 10 (each modules contain 4 to 10 channels) |
500 MB/ 1.2 GB (internal), 32 GB (SD) | DC voltage, Standard signal, Thermocouple, RTD, Digital input, DC current`, resistance | 100 to 240 VAC |
GX90XA-10-U2 | 10 | N/A | min. 10 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, RTD, contact (solid state relay scanner type) | N/A |
GX90XA-10-L1 | 10 | N/A | min. 500 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, contact (Low withstand voltage solid state relay scanner type) |
N/A |
GX90XA-10-T1 | 10 | N/A | min. 1 s (Scan interval) | N/A | N/A | DC voltage, thermocouple, contact (electromagnetic relay scanner type) |
N/A |
GX90XA-10-C1 | 10 | N/A | min. 10 ms (Scan interval) | N/A | N/A | DC current (mA) (solid state relay scanner type) | N/A |
GX90XA-10-V1 | 10 | N/A | min. 10 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, contact (Solid state relay scanner type), High withstand voltage (600 V double insulation, 1000 VDC basic insulation) |
N/A |
GX90XA-04-H0 | 4 | N/A | min. 1 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, RTD, contact (individual A/D type) |
N/A |
GX90XA-06-R1 | 6 | N/A | min. 10 ms (Scan interval) | N/A | N/A | 4-wire RTD, 4-wire resistance (solid state relay scanner type) |
N/A |
GX90YA | 4 | N/A | min. 100 ms (Output update interval) | N/A | N/A | Current output* | N/A |
GX90XD | 16 | N/A | 250Hz (The chattering filter : OFF) 125Hz (The chattering filter : ON) (Max. pulse period) |
N/A | N/A | Remote control input or operation recording* | N/A |
GX90YD | 6 | N/A | N/A | N/A | N/A | Alarm output* | N/A |
GX90WD | 14 | N/A | N/A | N/A | N/A | Remote control input or operation recording/alarm output* |
N/A |
GX90XP | 10 | N/A | Up to 20 kHz (Input range) | N/A | N/A | Pulse signal data acquisition, integral count* | N/A |
GX90UT | 26 | N/A | 100 ms or 200 ms (Scan control interval) | N/A | N/A | PID control (2 loop)* | N/A |