YOKOGAWA GM10
Description:
Key Specifications
NUMBER OF CHANNELS
4 to 100 (single unit)SAMPLING RATE
shortest scan interval: 1msMEMORY
500 MB/ 1.2 GB (internal), 32 GB (SD)TYPE OF MEASUREMENT
DC voltage, Standard signal, Thermocouple, RTD, Digital input, DC current, resistanceFeatures
01
Easily determine the quality of processes and equipment with the Health Monitor function
By easily creating predictive detection models from past recorded OK/NG (Not Good) data and loading it into GM, you can detect prediction of abnormalities in manufacturing equipment and product quality degradation at an early stage. And because health scores which show the degree of normal and abnormal data consider correlations among multiple data to make determinations, they can capture prediction of abnormalities that are difficult for humans to detect.
- Maximum number of channels: 20
- Shortest recording interval: 100 ms
- Target channels: I/O channel, math channel, and communication channel
- Files that can be used to create a predictive detection model:
[Yokogawa products] SMARTDAC+, DXAdvanced
[Other companies’ products] KEYENCE : TR-W1000 and TR-W500 csv file, CHINO : KR2000 and KR3000 csv file, EUROTHERM : 6100A and 6180A csv file
Health monitor function empowers you to:
- Perform maintenance and repair before equipment malfunctions and product quality degradation
- Quantify degrees of equipment deterioration and quality degradation
- Easily build equipment/quality predictive detection systems on site
02
Dual interval measurement with two different scan intervals
Users have the ability to choose two different scan intervals on a single GM system. This allows users the flexibility to measure various types of inputs with two different scan intervals in a single system. For example, this provides for efficient, simultaneous measurement of signals with slow fluctuations such as temperature, and fast-changing signals such as pressure and vibration. Modules can be assigned to measurement groups.
03
Increase channels by adding additional block modules
- Expand one, or multiple module at a time
- Unique design houses modules in linked module bases
- Module base ensures linkage (slide locks and mounting screws also available)
- Modules can be inserted and removed from the front panel for easy maintenance
04
Select from a wide range of I/O modules
Select modules according to your application. Noise-resistant, magnetic relay types also available. All modules have removable terminal blocks for easy wiring. The same modules used in the SMARTDAC+TM series.
Model | Name | Measurement/Application | Channels |
---|---|---|---|
GX90XA-10-U2 | Analog input module | DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (solid state relay scanner type) | 10 |
GX90XA-10-L1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Low withstand voltage solid state relay scanner type) | 10 | |
GX90XA-10-T1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (electromagnetic relay scanner type) | 10 | |
GX90XA-10-C1 | DC current (mA) (solid state relay scanner type) | 10 | |
GX90XA-10-V1 | DC voltage, DC current (with external shunt resistor connected), thermocouple, contact (Solid state relay scanner type) | 10 | |
GX90XA-04-H0 | DC voltage, DC current (with external shunt resistor connected), thermocouple, RTD, contact (individual A/D type) | 4 | |
GX90XA-06-R1 | 4-wire RTD, 4-wire resistance (solid state relay scanner type) | 6 | |
GX90YA | Analog output module | Current output | 4 |
GX90XD | Digital input module | Remote control input or operation recording | 16 |
GX90YD | Digital output module | Alarm output | 6 |
GX90WD | Digital input/output module | Remote control input or operation recording/alarm output | DI:8/DO:6 |
GX90XP | Pulse input module | Pulse signal data acquisition, integral count | 10 |
GX90UT | PID control module | PID control (2 loop) | AI:2/AO:2 DI:8/DO:8 |
Internal memory and max. I/O channels
Type | Internal memory | Max. input/output channels* | |
---|---|---|---|
GM10-1 | 500 MB | Single-unit configuration | 0 to 100 |
Multi-unit configuration | 0 to 100 | ||
GM10-2 | 1.2 GB | Single-unit configuration | 0 to 100 |
Multi-unit configuration | 0 to 420 |
Model
Model | Channels | Bandwidth | Sampling Rate | Number of modules | Memory | Measurement type | Power |
---|---|---|---|---|---|---|---|
GM10 | 4 to 100 (single unit) | N/A | min. 1 ms (Scan interval) | 10 (each modules contain 4 to 10 channels) |
500 MB/ 1.2 GB (internal), 32 GB (SD) | DC voltage, Standard signal, Thermocouple, RTD, Digital input, DC current`, resistance | 100–240 VAC 12-28 VDC |
GX90XA-10-U2 | 10 | N/A | min. 10 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, RTD, contact (solid state relay scanner type) | N/A |
GX90XA-10-L1 | 10 | N/A | min. 500 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, contact (Low withstand voltage solid state relay scanner type) |
N/A |
GX90XA-10-T1 | 10 | N/A | min. 1 s (Scan interval) | N/A | N/A | DC voltage, thermocouple, contact (electromagnetic relay scanner type) |
N/A |
GX90XA-10-C1 | 10 | N/A | min. 10 ms (Scan interval) | N/A | N/A | DC current (mA) (solid state relay scanner type) | N/A |
GX90XA-10-V1 | 10 | N/A | min. 10 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, contact (Solid state relay scanner type), High withstand voltage (600 V double insulation, 1000 VDC basic insulation) |
N/A |
GX90XA-04-H0 | 4 | N/A | min. 1 ms (Scan interval) | N/A | N/A | DC voltage, thermocouple, RTD, contact (individual A/D type) |
N/A |
GX90XA-06-R1 | 6 | N/A | min. 10 ms (Scan interval) | N/A | N/A | 4-wire RTD, 4-wire resistance (solid state relay scanner type) |
N/A |
GX90YA | 4 | N/A | min. 100 ms (Output update interval) | N/A | N/A | Current output* | N/A |
GX90XD | 16 | N/A | 250Hz (The chattering filter : OFF) 125Hz (The chattering filter : ON) (Max. pulse period) |
N/A | N/A | Remote control input or operation recording* | N/A |
GX90YD | 6 | N/A | N/A | N/A | N/A | Alarm output* | N/A |
GX90WD | 14 | N/A | N/A | N/A | N/A | Remote control input or operation recording/alarm output* |
N/A |
GX90XP | 10 | N/A | Up to 20 kHz (Input range) | N/A | N/A | Pulse signal data acquisition, integral count* | N/A |
GX90UT | 26 | N/A | 100 ms or 200 ms (Scan control interval) | N/A | N/A | PID control (2 loop)* | N/A |
SLIDE TO VIEW MORE