Key Specifications
RATED POWER
200/ 400/ 1200/ 2400WVOLTAGE RANGE
0.25V to 150VCURRENT RANGE
40A-240AINPUT POWER
50VA-95VACategory
Features
Maximum slew rate of 60 A/μs
Achieving a rise time of 4 μs to reach the rated current of the electronic load. Power supply evaluation demands a fast transient response which the PLZ-5W series achieves with ease.
Adjustable slew rate
The speed of change can be set when the current is changed.The slew rate setting will function in the following instances.
When the setting is changed to vary the current value (including the switching function).
When the current value is changed using external control in constant current (CC) mode.
When the current value is changed while the load is on.
The slew rate is set according to the current range as an amount of current change per unit of time. Moreover, a common value is set for the rise and fall speeds. In CC mode and ARB mode, the slew rate can be set regardless of whether the load is on or off.
Switching function
Switching mode can be performed at up to kHz while in CC and CR modes. The switching setting parameters such as switching level, frequency, and duty factor can be changed at any time, even while the load is on.
[Setting parameters]
Operation mode: CC and CR
Frequency setting range: 1 Hz to 100 kHz
Frequency setting resolution
1Hz to 10Hz 0.1Hz
11Hz to 100Hz 1Hz
110Hz to 1kHz 10Hz
1.1kHz to 10kHz 0.1kHz
10kHz to 100kHz 20kHz,50kHz,100kHz
Frequency setting accuracy: ±(0.5 % of set)
Duty factor, steps
1 Hz to 10 Hz 5.0% to 95.0%, in steps of 0.1%
11 Hz to 100 Hz
110 Hz to 1000 Hz
1.1 kHz to 10.0 kHz 5.0% to 95.0%, in steps of 1%
10 kHz ~100 kHz 10% to 90%, in steps of 10%
Model
Model | DC Voltage | Max. DC Current | DC Powe Capacity | Height | Input Power Connection | Input power |
---|---|---|---|---|---|---|
PLZ205W | 0.25 V to 150 V | 40 A | 200 W | 124mm | 100 Vac to 240 Vac (90 Vac to 250 Vac) single phase, continuous | 50 VAmax |
PLZ405W | 0.25 V to 150 V | 80 A | 400 W | 124mm | 100 Vac to 240 Vac (90 Vac to 250 Vac) single phase, continuous | 50 VAmax |
PLZ1205W | 0.25 V to 150 V | 240 A | 1200 W | 140mm | 100 Vac to 240 Vac (90 Vac to 250 Vac) single phase, continuous | 85 VAmax |
PLZ2405WB | 0.25 V to 150 V | 480 A | 2400 W | 86mm | 100 Vac to 240 Vac (90 Vac to 250 Vac) single-phase, continuous, 47 Hz to 63 Hz | 95 VAmax |
PLZ6005W SR | 0.25V to 150V | 1200 A | 6000 W | 370mm | 90 V to 250 V auto-select; no special wiring is required | |
PLZ10005W SR | 0.25V to 150V | 2160 A | 10800 W | 567mm | 90 V to 250 V auto-select; no special wiring is required | |
PLZ15005W SR | 0.25V to 150V | 2160 A | 15600 W | 748mm | 90 V to 250 V auto-select; no special wiring is required | |
PLZ20005W SR | 0.25V to 150V | 2160 A | 20400 W | 930mm | 90 V to 250 V auto-select; no special wiring is required |