Key Specifications
RATED POWER
5 kW, 10 kW, 15 kWVOLTAGE RANGE
0–10V to 0–2000VCURRENT RANGE
0–20A to 0–510AINPUT POWER
208–480V 3ph, ≤40AFeatures
True Autoranging – Advantages for Test
All EA bidirectional DC power supplies offer true autoranging. This means that the full source and sink power of the devices is available over additional operating ranges. The lower the current required in these ranges the higher the voltage available. Higher currents are possible at lower voltages. This allows a wider range of DUTs to be tested with a single power supply. EA’s autoranging feature provides full power, output as well as input, starting at 33% of system voltage and also current.
- Save budget and space
- No oversizing supply
- One supply tests more
- Versatile for future tests
Regenerative Energy Recovery
The PSB is bidirectional, meaning it can source (provide) or sink (absorb) current and regenerate that current to the local power grid with up to 96% efficiency. The built-in electronic load function is regenerative, making the PSB a very green solution on top of minimizing investment and test equipment space.
- Save electricity + costs
- Efficiency approx. 96%
- Quick return on investment
- Environmentally friendly
Waveform Function Generator
A common need for DC power supplies is to deliver the output voltage or current with a pattern other than a straight-line DC signal. EA’s built-in function generator includes options for sine, triangle, rectangle, and trapezoid waveforms, as well as custom arbitrary wave forms. Additionally, there are configuration tools for ramping, UI and IU tables, and simulations for fuel cells and photovoltaics.
If the integral master-slave bus and share bus are used, a multi device system behaves as a single device. The master- slave bus and the share bus are simply connected to each device. With the master-slave bus the system data such as total power and total current are collected and shown in the master device. Warnings and alarms of the slave devices are shown clearly in the display. The share bus provides an equal load distribution to the individual devices.
Battery test mode
SCPI and ModBus protocol
Model
Model | DC Voltage | DC Current | DC Power | Height | Power Connection | Input Power |
---|---|---|---|---|---|---|
PSB 10010-170 | 0 - 10 V | 0 - 170 A | 0 - 1700 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10060-170 | 0 - 60 V | 0 - 170 A | 0 - 5000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10080-170 | 0 - 80 V | 0 - 170 A | 0 - 5000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10200-70 | 0 -200 V | 0 - 70 A | 0 - 5000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10360-40 | 0 - 360 V | 0 - 40 A | 0 - 5000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10500-30 | 0 - 500 V | 0 - 30 A | 0 - 5000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10750-20 | 0 - 750 V | 0 - 20 A | 0 - 5000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10010-340 | 0 - 10 V | 0 - 340 A | 0 - 3400 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10060-340 | 0 - 60 V | 0 - 340 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10080-340 | 0 - 80 V | 0 - 340 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10200-140 | 0 -200 V | 0 - 140 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10360-80 | 0 - 360 V | 0 - 80 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10500-60 | 0 - 500 V | 0 - 60 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10750-40 | 0 - 750 V | 0 - 40 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 11000-30 | 0 - 1000 V | 0 - 30 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 11500-20 | 0 - 1500 V | 0 - 20 A | 0 - 10000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10010-510 | 0 - 10 V | 0 - 510 A | 0 - 5100 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | |
PSB 10060-510 | 0 - 60 V | 0 - 510 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |
PSB 10080-510 | 0 - 80 V | 0 - 510 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |
PSB 10200-210 | 0 -200 V | 0 - 210 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |
PSB 10360-120 | 0 - 360 V | 0 - 120 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |
PSB 10500-90 | 0 - 500 V | 0 - 90 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |
PSB 10750-60 | 0 - 750 V | 0 - 60 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |
PSB 11000-40 | 0 - 1000 V | 0 - 40 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |
PSB 11500-30 | 0 - 1500 V | 0 - 30 A | 0 - 15000 W | 3U | 208 V / 380 V / 400 V / 480 V ±10%, 3ph AC | 40A @400V |