Key Specifications
NUMBER OF CHANNELS
Up to 128 Single UnitSAMPLING RATE
Up to 200 MS/sMEMORY
Standard: 1 Gpoint (up to 500 Mpoints per channel)/M1 option: 4 Gpoints (up to 2 Gpoints per channel)
/M2 option: 8 Gpoints (up to 4 Gpoints per channel)
TYPE OF MEASUREMENT
Voltage, Current, Temperature, Strain,Acceleration, Frequency, Logic,
CAN, LIN, CAN FD, SENT
Category
Features
New high-speed module and 10 Gbps Ethernet
T200 MS/s 14 Bit Isolation Module
Accurately captures switching waveforms of inverters and fastmoving noises around the power supply.
Isolated input of up to 1000 V
ADC resolution 14 bit
Wide band of 40 MHz
Up to 20 seconds of continuous acquisition
10 GE data transfer (/C60 option)
Using 10 Gbps Ethernet, up to 20 MS/s of data can be stored in real time on a PC. An SFP+ module, a fiber optic cord, and the PC software IS8000 are used for data transfer. *Please use a commercially available SFP+ module and a 10 GE fiber optic cord.When transferring files, high speed transfer is not possible.
8 G points large memory (/M2 option)
SSD recording (/ST1 or /ST2 option)
The 512 GB internal SSD can record for long periods of time at up to 2 MS/s. Waveforms from dual capture can also be recorded, which is useful for in-vehicle endurance testing and capturing rare spontaneous events.
Flash acquisition (/ST2 option)
Long time recording at up to 20 MS/s, which is 100 times faster than the previous model, is available. You can capture data anywhere you cannot bring a PC such as on-vehicle or field testing. The flash memory is non-volatile, so the captured data stays in the instrument even after turning off the power. Data can later be transfered to a PC.
Deletion of the recorded data on the flash memory is not done for each recorded data but for all the data at once.
When transferring recorded data to a PC, please use the IS8000 or re-save the data in WDF format.
Model
Model | Channels | Bandwidth | Sampling Rate | Number of modules | Memory | Measurement type | Power |
---|---|---|---|---|---|---|---|
DL950 | 32 channels (when 4-CH modules are used in all slots) 128 channels (when 16 CH temperature/voltage modules are used in all slots) |
40 MHz Max | 10 S/s to 200 MS/s | 8 | Standard: 1 Gpoint (up to 500 Mpoints per channel) /M1 option: 4 Gpoints (up to 2 Gpoints per channel) /M2 option: 8 Gpoints (up to 4 Gpoints per channel) |
Voltage, Current, Temperature, Strain, Acceleration, Frequency, Logic, CAN, LIN, CAN FD, SENT | 100 to 240 V AC |
720212 | 2 | 40 MHz | 200 MS/s | N/A | N/A | Analog Voltage; High speed, high voltage, isolated | N/A |
720211 | 2 | 20 MHz | 100 MS/s | N/A | N/A | Analog Voltage; High speed, high voltage, isolated | N/A |
720250 | 2 | 3 MHz | 10 MS/s | N/A | N/A | Analog Voltage; High noise immunity | N/A |
701251 | 2 | 300 kHz | 1 MS/s | N/A | N/A | Analog Voltage; High sensitivity range (1 mV/div), low noise (±100 µVtyp.), and high noise immunity | N/A |
720256 | 4 | 3 MHz | 10 MS/s | N/A | N/A | Analog Voltage; 4 CH BNC input low noise, high noise immunity | N/A |
720254 | 4 | 300 kHz | 1 MS/s | N/A | N/A | Analog Voltage; 4 CH BNC inputlow noise, high noise immunity | N/A |
701255 | 2 | 3 MHz | 10 MS/s | N/A | N/A | Analog Voltage; High speed, non-isolated | N/A |
720268 | 2 | 300 kHz | 1 MS/s | N/A | N/A | Analog Voltage; With AAF, RMS, and high noise immunity | N/A |
720220 | 16 | 5 kHz | 200 kS/s | N/A | N/A | Analog Voltage; 16 CH voltage measurement (Scan-type) | N/A |
701261 | 2 | 40 kHz (Voltage), 100 Hz (Temperature) |
100 kS/s (Voltage), 500 S/s (Temperature) |
N/A | N/A | Analog Voltage & Temperature; Thermocouple (K, E, J, T, L, U, N, R, S, B, W, KP/AuFe) |
N/A |
701262 | 2 | 40 kHz (Voltage), 100 Hz (Temperature) |
100 kS/s (Voltage), 500 S/s (Temperature) |
N/A | N/A | Analog Voltage & Temperature; Thermocouple (K, E, J, T, L, U, N, R, S, B, W, KP/AuFe), with AAF |
N/A |
701265 | 2 | 100 Hz | 500 S/s (Voltage), 500 S/s (Temperature) |
N/A | N/A | Analog Voltage & Temperature; Thermocouple (K, E, J, T, L, U, N, R, S, B, W, KP/AuFe), high sensitivity range (0.1 mV/div) |
N/A |
720266 | 2 | 15 Hz | 125 S/s (Voltage), 125 S/s (Temperature) |
N/A | N/A | Analog Voltage & Temperature; Thermocouple (K, E, J, T, L, U, N, R, S, B, W, KP/AuFe), high sensitivity range (0.1 mV/div), Low noise |
N/A |
720221 | 16 | 600 Hz | 10 S/s | N/A | N/A | Analog Voltage & Temperature; 16 CH voltage or temperature measurement (scan method) Thermocouple (K, E, J, T, L, U, N, R, S, B, W, KP/AuFe) |
N/A |
701270 | 2 | 20 kHz | 100 kS/s | N/A | N/A | Strain; Supports strain NDIS, 2, 5, 10 V built-in bridge power supply |
N/A |
701271 | 2 | 20 kHz | 100 kS/s | N/A | N/A | Strain; Supports strain DSUB, 2, 5, 10 V built-in bridge power supply, and shunt CAL |
N/A |
701275 | 2 | 40 kHz | 100 kS/s | N/A | N/A | Analog Voltage, Acceleration; Built-in anti-aliasing filter, Supports built-in amp type acceleration sensors (4 mA/22 V) | N/A |
720281 | 2 | resolution 625 ps | 1 MS/s | N/A | N/A | Frequency; Measurement frequency of 0.01 Hz to 500 kHz, Measured parameters (frequency, RPMs, RPSs, period, duty cycle, power supply frequency, pulse width, pulse integration, and velocity) |
N/A |
720230 | 8bit x 2 | N/A | 10 MS/s | N/A | N/A | Logic; (8 bit/port) × 2, compatible with four types of logic probe (sold separately) | N/A |
720242 | 60 signal x 2 | N/A | 100 kS/s | N/A | N/A | CAN/ CAN FD; CAN/CAN FD port × 2, extraction of up to 32-bit data | N/A |
720241 | 60 signal x 2 | N/A | 100 kS/s | N/A | N/A | CAN, LIN; CAN port × 1 (CAN FD is not supported), LIN port × 1 | N/A |
720243 | 11 data x 2 | N/A | 100 kS/s | N/A | N/A | SENT; Supported protocol: SAE J2716 | N/A |